| in | mm | |
| Pitch | 2.0 | 50.8 |
| Minimum Width (See Product Notes.) | 12 | 304.8 |
| Maximum Width | 60 | 1524 |
| Width Increments | 0.50 | 12.7 |
| Opening Size (approximate) | 0.38 x 0.64 | 9.5 x 16.5 |
| Open Area (fully extended, see Product Notes) | 44% | |
| Minimum Open Area (2.0 TR) | 23% | |
| Hinge Style | Open | |
- This belt has pinch points. See the Safety section in the Intralox Conveyor Belting Installation, Maintenance & Troubleshooting Manual for more information.
- Contact Intralox for precise belt measurements and stock status before designing equipment or ordering a belt.
- Do not use in spiral conveyor systems.
- Open area calculations for S2700 Dual Turning 2.0 are unique to this style, and are not directly comparable to other S2700 styles.
- Rods are inserted from the edge of the belt. No special tools are required.
- Each belt material has a default rod material. Other rod materials are available. Intralox can help identify the best belt and rod material combination for your application.
- Detailed material information is provided in Product Line.
- Turn ratio of 2.0 times belt width (measured from inside edge).
- When considering belt widths under 12 in (305 mm), contact Intralox Customer Service
- Contact Intralox for a spiral analysis and the preferred run direction on spiral applications.
| Belt Material | Default Rod Material, Diameter 0.24 in (6.1 mm) | Straight Belt Strength | Curved Belt Strength | Temperature Range (continuous)1 | Belt Mass | ||||
|---|---|---|---|---|---|---|---|---|---|
| lbf/ft | N/m | °F | °C | lb/ft² | kg/m² | ||||
| Acetal | Acetal | 1,700 | 24,800 | For curved belt strength calculations, contact Intralox Customer Service. | -50 to 200 | -46 to 93 | 1.84 | 8.98 | |
| Acetal | Nylon | 1,700 | 24,800 | -50 to 200 | -46 to 93 | 1.81 | 8.84 | ||
| SELM | Acetal | 1,060 | 15,500 | -50 to 200 | -46 to 93 | 1.42 | 6.93 | ||
| SELM | Nylon | 1,060 | 15,500 | -50 to 212 | -46 to 100 | 1.40 | 6.84 | ||
Belt functions mechanically up to 240°F (116°C). Belt used in the temperature window of 212°F to 240°F (100°C to 116°C) is not FDA-compliant.